Difference between revisions of "RMU build Gen-1.5"
From Internet Computer Wiki
Katie.peters (talk | contribs) |
Katie.peters (talk | contribs) (Added more links) |
||
Line 33: | Line 33: | ||
* B. Optional: [[RMU build Gen-1.5: IV. Best Practices - B. Install RACADM Tool on RMU|Install RACADM Tool On RMU (Dell Nodes)]] | * B. Optional: [[RMU build Gen-1.5: IV. Best Practices - B. Install RACADM Tool on RMU|Install RACADM Tool On RMU (Dell Nodes)]] | ||
* C. Recommended: [[RMU build Gen-1.5: IV. Best Practices - C. Dell OpenManage Enterprise|Dell OpenManage Enterprise (OME) (Dell Nodes)]] | * C. Recommended: [[RMU build Gen-1.5: IV. Best Practices - C. Dell OpenManage Enterprise|Dell OpenManage Enterprise (OME) (Dell Nodes)]] | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
* D. Recommended: [[RMU build Gen-1.5: IV. Best Practices - D. Update Firmware on SuperMicro Nodes|Update Firmware On SuperMicro Nodes]] | * D. Recommended: [[RMU build Gen-1.5: IV. Best Practices - D. Update Firmware on SuperMicro Nodes|Update Firmware On SuperMicro Nodes]] | ||
* E. Recommended: [[RMU build Gen-1.5: IV. Best Practices - E. Enable Remote Access to Servers Console|Enable Remote Access To Servers Console (Dell Nodes)]] | * E. Recommended: [[RMU build Gen-1.5: IV. Best Practices - E. Enable Remote Access to Servers Console|Enable Remote Access To Servers Console (Dell Nodes)]] | ||
− | |||
− | |||
− | |||
− | |||
− | |||
− | |||
=== V. Reference Information === | === V. Reference Information === | ||
+ | |||
+ | * [[RMU build Gen-1.5: V. Reference Information - Internal Network Layout|Internal Network Layout]] | ||
+ | * [[RMU build Gen-1.5: V. Reference Information - RMU Cabling|RMU Cabling]] | ||
+ | * [[RMU build Gen-1.5: V. Reference Information - Checking number of internal drives|Checking number of internal drives]] |
Revision as of 18:09, 1 March 2024
Process for building a new RMU for the Gen 1.5 ICR
The following guide describes how DFINITY monitors their ICR Sites. If you choose to follow this guide, completing everything up to Best Practices will get you remote access to the RMU and the ability to add additional services via teleport. The Best Practices section does introduce some services that greatly improve the overall experience such as being able to update firmware on all servers remotely.
I. Prerequisites
II. Proxmox
Once Proxmox is installed and reachable (Step II.A), the rest can be done remotely.
- A. Install Proxmox
- B. Update Proxmox
- C. Download CT Templates
- D. Download ISO Images
- E. Add LAN Network Device
II. Teleport
This service will provide you secure remote access to all of the services installed on your RMU.
- A. Create Teleport CT
- B. Install Teleport Software
- C. Share RMU Services Via Teleport
- D. Teleport Notes
III. MaaS (Metal as a Service)
- A. Create Proxmox CT
- B. Install MaaS Software via APT (for a Container)
- C. Share Services Via Teleport
- D. Initial Configuration of MaaS Server
- E. Configure DHCP Subnet on MaaS
IV. Best Practices
- A. Recommended: Proxmox Security
- B. Optional: Install RACADM Tool On RMU (Dell Nodes)
- C. Recommended: Dell OpenManage Enterprise (OME) (Dell Nodes)
- D. Recommended: Update Firmware On SuperMicro Nodes
- E. Recommended: Enable Remote Access To Servers Console (Dell Nodes)