RMU build Gen-1.5: V. Reference Information - Internal Network Layout
From Internet Computer Wiki
This page is part of the Gen-1.5 RMU build runbook.
.
All Gen-1 data centers are recommended to use the following private static IP addresses for the Management network:
MaaS DHCPv4 BMC range will be 10.10.100.50-10.10.100.99 - This allows for an RMU, fw01, fw02, and 46 IC BMC addresses.
Name | “Management” Private IPv4 10.10.100.0/24 | “BMC” IPv4
10.10.100.0/24 |
Management Public IPv4 | Public IPv4 Uplink (/28) | Public IPV6 Uplink | “Delegated” IPv6 Prefix (::/64) | Notes |
---|---|---|---|---|---|---|---|
Upstream Provider IPv6 Uplink Default Router | ${MGMTIPV4}+1 | ${PUBLICIPV4}+1 | ${UPLINKIPV6}::1 | Upstream provider may use something like VRRP on :2/:3 | |||
RMU | 10.10.100.1 | 10.10.100.50 | ${MGMTIPV4}+2 | ${DELEGATED}::EIP64 | |||
fw01/router01 | ? | 10.10.100.51 | ${UPLINKIPV6}::4 | ${DELEGATED}::1 | |||
fw02/router02 or bn01 | ? | 10.10.100.52 | ${UPLINKIPV6}::5 | ${DELEGATED}::2 | |||
msw01 | 10.10.100.10 | ||||||
sw01 | 10.10.100.11 | ||||||
sw02 | 10.10.100.12 | ||||||
sw03 | 10.10.100.13 | ||||||
sw04 | 10.10.100.14 | ||||||
teleport | 10.10.100.22 | ${DELEGATED}::EIP64 | |||||
maas | 10.10.100.20 | ||||||
monitoring | 10.10.100.21 | ||||||
ome | 10.10.100.23 | ||||||
iDRAC / BMC | 10.10.100.53-10.10.100.99 | ${DELEGATED}::EIP64 | |||||
Unallocated | 10.100.100.100-10.100.100.254 |