RMU build Gen-1.5: V. Reference Information - Internal Network Layout

From Internet Computer Wiki
Revision as of 18:01, 1 March 2024 by Katie.peters (talk | contribs) (Created page)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search

This page is part of the Gen-1.5 RMU build runbook.

.

All Gen-1 data centers are recommended to use the following private static IP addresses for the Management network:

MaaS DHCPv4 BMC range will be 10.10.100.50-10.10.100.99 - This allows for an RMU, fw01, fw02, and 46 IC BMC addresses.

Name “Management” Private IPv4 10.10.100.0/24 “BMC” IPv4

10.10.100.0/24

Management Public IPv4 Public IPv4 Uplink (/28) Public IPV6 Uplink “Delegated” IPv6 Prefix (::/64) Notes
Upstream Provider IPv6 Uplink Default Router ${MGMTIPV4}+1 ${PUBLICIPV4}+1 ${UPLINKIPV6}::1 Upstream provider may use something like VRRP on :2/:3
RMU 10.10.100.1 10.10.100.50 ${MGMTIPV4}+2 ${DELEGATED}::EIP64
fw01/router01 ? 10.10.100.51 ${UPLINKIPV6}::4 ${DELEGATED}::1
fw02/router02 or bn01 ? 10.10.100.52 ${UPLINKIPV6}::5 ${DELEGATED}::2
msw01 10.10.100.10
sw01 10.10.100.11
sw02 10.10.100.12
sw03 10.10.100.13
sw04 10.10.100.14
teleport 10.10.100.22 ${DELEGATED}::EIP64
maas 10.10.100.20
monitoring 10.10.100.21
ome 10.10.100.23
IC hosts 10.10.100.53-10.10.100.99 ${DELEGATED}::EIP64
Unallocated 10.100.100.100-10.100.100.254