Difference between revisions of "Error Handling inside Internet Computer"
Line 75: | Line 75: | ||
===== UnknownManagementMessage: StatusCode 518 ===== | ===== UnknownManagementMessage: StatusCode 518 ===== | ||
− | Inside each subnet, there is a special canister called ''management canister''<ref>https://internetcomputer.org/docs/current/references/ic-interface-spec/#ic-management-canister</ref> with predefined methods. | + | Inside each subnet, there is a special canister called ''management canister''<ref>https://internetcomputer.org/docs/current/references/ic-interface-spec/#ic-management-canister</ref> with predefined methods. If someone calls a management canister and specifies a method |
===== InvalidManagementPayload: StatusCode 519 ===== | ===== InvalidManagementPayload: StatusCode 519 ===== |
Revision as of 23:03, 24 October 2022
This Page is Still Work in Progress
SubnetOverSubscribed: StatusCode 101
This error is raised when installing a new canister or increasing memory allocation in the canister, and no compute allocation or memory capacity is left in the subnet.
MaxNumberOfCanistersReached: StatusCode 102
There is an option in the NNS registry to set a max limit on the number of canisters in a subnet. When a new canister is created, the subnet checks if this maximum limit is reached and throws an error accordingly. Currently, we don’t limit the number of canisters in a subnet.
CanisterOutputQueueFull: StatusCode 201
Internet Computer allows one canister to call another canister. These outgoing inter-canister canister calls are placed in the output queues of the canister. There is a currently a limit of 500 messages per output queue. CanisterOutputQueueFull error is thrown when this limit is reached.
IngressMessageTimeout: StatusCode 202
A user can call a method of a canister by sending an ingress message. The ingress messages go through consensus protocol. The ingress messages that are accepted by the consensus layer are pushed into ingress queue of the corresponding canister. The canister processes the messages in its ingress queue in order. If the system is quite loaded and if a message stays in the ingress queue for over 5 minutes, then IngressMessageTimeout error is thrown.
CanisterNotFound: StatusCode 301
When a user/canister calls a canister which is not found, CanisterNotFound error is thrown.
CanisterMethodNotFound: StatusCode 302
Each canister exposes a few methods that can be invoked by anyone. When a user/canister calls another canister, they need to specify a method to be invoked in the target canister. If this method is not found in the target canister, CanisterMethodNotFound error is thrown.
CanisterAlreadyInstalled: StatusCode 303
When anyone attempts to create a new canister, they can optionally specify a canister id that is to be used for the newly created canister. If the specified canister id is already taken (another canister exists with the specified canister id), then CanisterAlreadyInstalled error is thrown.
CanisterWasmModuleNotFound: StatusCode 304
A canister can be installed in a two step process. In the first step, a canister is created in a subnet and alloted a canister id. At this point, the canister is empty and does not contain any code. In the second step, the controller of the canister can install a Wasm module in the canister. If anyone sends an update/query call to the canister before the wasm module is installed, then CanisterWasmModuleNotFound error is thrown.
InsufficientTransferFunds: StatusCode 401
This error code is deprecated and currently not used anywhere. Earlier, one canister can transfer ICP to another canister. If a canister tries to send more ICP than it owns, InsufficientTransferFunds is thrown. It is later decided that all ICP holdings should be maintained in a ledger in the Network Nervous System, and the only way to transfer is to make a transaction in the ledger. As one canister can no longer transfer ICP to another canister, this error code is deprecated.
InsufficientMemoryAllocation: StatusCode 402
The controller of a canister can specify a limit on how much memory the canister could use. If this memory allocation is too low for the canister to function properly, then InsufficientMemoryAllocation error is thrown.
InsufficientCyclesForCreateCanister: StatusCode 403
When anyone tries to create a new canister, they need to spend at least 2 trillion cycles. If they do not own these funds, then InsufficientCyclesForCreateCanister error is thrown.
SubnetNotFound: StatusCode 404
CanisterOutOfCycles: StatusCode 501
Each canister stores some cycles. When anyone sends a message to a canister, the canister spends a few cycles from its account to process the message. When someone sends a message and the canister doesn’t have enough cycles to process the message, CanisterOutOfCycles error is thrown.
CanisterTrapped: StatusCode 502
This error is thrown if the canister panicked somewhere or throws an error.
CanisterCalledTrap: StatusCode 503
This error is thrown if the canister explicitly decided to call IC0 System API trap
method.
CanisterContractViolation: StatusCode 504
CanisterInvalidWasm: StatusCode 505
CanisterDidNotReply: StatusCode 506
CanisterOutOfMemory: StatusCode 507
CanisterStopped: StatusCode 508
CanisterStopping: StatusCode 509
CanisterNotStopped: StatusCode 510
CanisterStoppingCancelled: StatusCode 511
CanisterInvalidController: StatusCode 512
CanisterFunctionNotFound: StatusCode 513
CanisterNonEmpty: StatusCode 514
CanisterRejectedMessage: StatusCode 516
InterCanisterQueryLoopDetected: StatusCode 517
UnknownManagementMessage: StatusCode 518
Inside each subnet, there is a special canister called management canister[1] with predefined methods. If someone calls a management canister and specifies a method
InvalidManagementPayload: StatusCode 519
InsufficientCyclesInCall: StatusCode 520
CanisterWasmEngineError: StatusCode 521
CanisterWasmEngineError error is thrown by the Internet Computer if WASM runtime library throws any error.
CanisterInstructionLimitExceeded: StatusCode 522
CanisterInstallCodeRateLimited: StatusCode 523
After a canister is created, the controller of the canister can upgrade the WASM code inside the canister. If the controller upgrades the canister too many times or if the install_code
has a lot of instructions, then CanisterInstallCodeRateLimited error is thrown.
CanisterMemoryAccessLimitExceeded: StatusCode 524
A canister can store up to 32 GB of memory. In a single canister call, the canister is allowed to access up to 8 GB of memory. If a canister accesses more memory than the limit in a single canister call, CanisterMemoryAccessLimitExceeded error is thrown.